  Datasheet File OCR Text:
 110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
FEATURES * 1 to 50 mbar, 1 to 30 "H2O gage or differential pressure (custom calibrations available) * 1...6 V or 4...20 mA output * Internal supply regulation * Precision temperature compensated and calibrated * Special calibrations for small volumes on request
SERVICE
Non-corrosive, non-ionic working fluids such as dry air and dry gases.
Scale: 1 cm 1 inch
SPECIFICATIONS
Maximum ratings
ELECTRICAL CONNECTION
1...6 V output version
Supply voltage 110L...-PCB 430L...-PCB1 Maximum load current (110L...-PCB only) source sink Temperature limits Storage Operating Compensated Lead temperature(4 sec soldering) Humidity limits (pressure inlets only)
12...24 V 12...36 V 20 mA 10 mA -25 to 85C -10 to 70C 0 to 50C 300C 0 - 80 %RH
430L...-PCB
+Vs 12 to 24 V Vout V -Vs
110L...-PCB
4...20 mA output version
+Vs
12 to 36 V
-Vs
V RL
GND
January 2007 / 006
1/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
1...6 V output version (unless otherwise noted VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Operating pressure3 differential devices 112LP02D-PCB 112LP05D-PCB 112LP10D-PCB 112LP25D-PCB 112LP50D-PCB 113LP01D-PCB 113LP02D-PCB 113LP05D-PCB 113LP10D-PCB 113LP25D-PCB 113LP50D-PCB 112LU01D-PCB 112LU02D-PCB 112LU05D-PCB 112LU10D-PCB 112LU20D-PCB 112LU30D-PCB 113LU01D-PCB 113LU02D-PCB 113LU05D-PCB 113LU10D-PCB 113LU20D-PCB 113LU30D-PCB 112L...-PCB 113L...-PCB 112L...-PCB 113L...-PCB
Min.
0 0 0 0 0 -1 -2 -5 -10 -25 -50 0 0 0 0 0 -1 -2 -5 -10 -20 -30 0.95 3.4 4.9 2.4
Typ.
Max.
2 5 10 25 50 1 2 5 10 25 50 1 2 5 10 20 30 1 2 5 10 20 30 1.05 3.6 5.1 2.6
Proof Common mode pressure2 pressure
200 200 200 300 300 200 200 200 200 300 300 80 120 120 240 240 240 80 120 120 240 240 240 300 300 300 600 600 300 300 300 300 600 600 160 240 240 360 360 360 160 240 240 360 360 360
Unit
pressure/ vacuum devices3
mbar
differential devices
pressure/ vacuum devices3
"H2O
Zero pressure offset4 Full scale span5
Full scale output Output at lowest specified pressure 113L...-PCB Thermal effects Offset 113LP01D-PCB (0 to 50C)6 11...LP02D-PCB 11...LU01D-PCB all other devices Span 113LP01D-PCB 11...LP02D-PCB 11...LU01D-PCB all other devices Non-linearity and hysteresis (BSL)7 Long term stability8 Response time (10 to 90 %) Position sensitivity all 1 and 2 mbar devices all other devices Current consumption Power supply Offset rejection Span
1.0 3.5 5.0 2.5 6.0 1.0 0.08 0.04 0.04 0.02 0.08 0.04 0.04 0.02 0.1 0.5 1 0.5 0.1 4.2 0.05 0.05
V
0.20 0.10 0.10 0.05 0.20 0.10 0.10 0.04 0.25
%FSO/C
%FSO ms %FSO/g mA %FSO/V
2/6
January 2007 / 006
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
4...20 mA output version (unless otherwise noted VS = 15 V, RL = 100 , tamb = 25C)
Characteristics
Operating pressure3 differential devices 432LP01D-PCB 432LP02D-PCB 432LP05D-PCB 432LP10D-PCB 432LP25D-PCB 432LP50D-PCB 433LP01D-PCB 433LP02D-PCB 433LP05D-PCB 433LP10D-PCB 433LP25D-PCB 433LP50D-PCB 432LU01D-PCB 432LU02D-PCB 432LU05D-PCB 432LU10D-PCB 432LU20D-PCB 432LU30D-PCB 433LU01D-PCB 433LU02D-PCB 433LU05D-PCB 433LU10D-PCB 433LU20D-PCB 433LU30D-PCB 432L...-PCB 433L...-PCB 432L...-PCB 433L...-PCB
Min.
0 0 0 0 0 0 -1 -2 -5 -10 -25 -50 0 0 0 0 0 -1 -2 -5 -10 -20 -30 3.9 11.9 15.8 7.9
Typ.
Max.
1 2 5 10 25 50 1 2 5 10 25 50 1 2 5 10 20 30 1 2 5 10 20 30 4.1 12.1 16.2 8.1
Proof Common mode pressure2 pressure
200 200 200 200 300 300 200 200 200 200 300 300 80 120 120 240 240 240 80 120 120 240 240 240 300 300 300 300 600 600 300 300 300 300 600 600 160 240 240 360 360 360 160 240 240 360 360 360
Unit
pressure/ vacuum devices3
mbar
differential devices
pressure/ vacuum devices3
"H2O
Zero pressure offset4 Full scale span5
Full scale output Output at lowest specified pressure 433L...-PCB Thermal effects Offset (0 to 50C)6 43...LP01D-PCB 43...LP02D-PCB 43...LU01D-PCB all other devices Span 43...LP01D-PCB 43...LP02D-PCB 43...LU01D-PCB all other devices Non-linearity and hysteresis (BSL)7 Long term stability8 Response time (10 to 90 %) Position sensitivity all 1 and 2 mbar devices all 1 "H2O devices all other devices Current consumption (IL = 20 mA) Power supply Offset rejection Span
4.0 12.0 16.0 8.0 20.0 4.0 0.08 0.04 0.04 0.02 0.08 0.04 0.04 0.02 0.1 0.2 1 0.5 0.5 0.1 4.2 0.05 0.05
mA
0.20 0.10 0.10 0.05 0.20 0.10 0.10 0.04 0.25
%FSO/C
%FSO ms %FSO/g mA %FSO/V
January 2007 / 006
3/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
Specification notes:
1. 2. 3. 4. 5. 6. 7. 8. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when vacuum is applied to port A relative to port B. Calibrated after minimum 3 minutes warm-up time. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset. Thermal effects tested and guaranteed from 0 - 50C relative to 25C. All specifications shown are relative to 25C. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full-scale pressure. Change in output after one year or 1 million pressure cycles.
OUTPUT CHARACTERISTICS
1...6 V output versions Differential devices 112L...-PCB
6 Vout 5 V 4 3 2 1 0 20 40 60 80 100 % full scale pressure
1...6 V output versions Pressure/vacuum devices 113L...-PCB
6 Vout 5 V 4 3 2 1 0 -100 -50 0 50 100 % full scale pressure 3.5 V
4...20 mA output versions Differential devices 432L...-PCB
20 Iout 16 mA 12 8 4 0 20 40 60 80 100 % full scale pressure
4...20 mA output versions Pressure/vacuum devices 433L...-PCB
20 Iout 16 mA 12 8 4 0 -100
-50
0 50 100 % full scale pressure
4/6
January 2007 / 006
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
LOAD LIMITATION
4...20 mA output versions
1200 Ohm 1000 800 600 400 200
operating range
0
10
20
30 V Vsupply
OUTLINE DRAWING
30.0 18.3
30.5 port A 14.0 9.1 10.7 3 terminals 0.56 diam. 2 x 5.08 typ. 22.7 1 2 3 12.6
59.8
52.4
port B (high pressure port) 3.5 diam. 2 x mounting holes NOM 6.0
3
mass: 20 g PIN CONNECTION: Pin 1 2 3 Connection 1 - 6 V version 4 - 20 mA version +Vs -Vs Vout NC -Vs +Vs
4.8 diam.
dimensions in mm
January 2007 / 006
5/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
ORDERING INFORMATION
Operating pressure
0 - 1 mbar 0 - 2 mbar Differential/gage devices 0 - 5 mbar 0 - 10 mbar 0 - 25 mbar 0 - 50 mbar 0 1 mbar 0 2 mbar Pressure/vacuum devices 0 5 mbar 0 10 mbar 0 25 mbar 0 50 mbar 0 - 1"H2O 0 - 2"H2O Differential/gage devices 0 - 5"H2O 0 - 10"H2O 0 - 20"H2O 0 - 30"H2O 0 1"H2O 0 2"H2O Pressure/vacuum devices 0 5"H2O 0 10"H2O 0 20"H2O 0 30"H2O
Part number 1...6 V output
--112LP02D-PCB 112LP05D-PCB 112LP10D-PCB 112LP25D-PCB 112LP50D-PCB 113LP01D-PCB 113LP02D-PCB 113LP05D-PCB 113LP10D-PCB 113LP25D-PCB 113LP50D-PCB 112LU01D-PCB 112LU02D-PCB 112LU05D-PCB 112LU10D-PCB 112LU20D-PCB 112LU30D-PCB 113LU01D-PCB 113LU02D-PCB 113LU05D-PCB 113LU10D-PCB 113LU20D-PCB 113LU30D-PCB
4...20 mA output
432LP01D-PCB 432LP02D-PCB 432LP05D-PCB 432LP10D-PCB 432LP25D-PCB 432LP50D-PCB 433LP01D-PCB 433LP02D-PCB 433LP05D-PCB 433LP10D-PCB 433LP25D-PCB 433LP50D-PCB 432LU01D-PCB 432LU02D-PCB 432LU05D-PCB 432LU10D-PCB 432LU20D-PCB 432LU30D-PCB 433LU01D-PCB 433LU02D-PCB 433LU05D-PCB 433LU10D-PCB 433LU20D-PCB 433LU30D-PCB
Custom calibrations available
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
6/6
January 2007 / 006
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of 112LU01D-PCB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X